Free shipping on all ESP surge protectors 

ESP Next Gen Surge Protector

IN STOCK - ships in 2-3 business days

      Made in the USA

      ESP Surge Protector Product Comparison Chart



      Features

      *An optional interface cord (Part #XG-PCS-IC-1) is required to connect the Next Gen to a computer. Next Gen software (free download from the Software tab below) must be installed on the host computer.

      • Patented Multi-Stage industrial surge/spike protection
      • Industrial EMI/RFI noise filtering
      • Catastrophic under & over voltage protection (CouVS®) with software programmable thresholds
      • Wiring fault detection
      • Zero-cross voltage turn-on
      • Hybrid Switch technology
      • ETL Cat5e Network surge protection (RJ-45)
      • Phone surge protection (RJ-11) with DSL filter
      • Inrush Current Elimination (ICE®)
      • Under-voltage event recorder (up to 999 events)
      • Over-voltage event recorder (up to 999 events)
      • Power outage event recorder (up to 999 events)
      • Surge event recorder (up to 999 events)
      • Event time stamp recorder (up to 60 events)
        • records time between events
      • LCD Event Monitor Display
        • Under-voltage events
        • Over-voltage events
        • Power outage events
        • Surge events
        • Last recorded event type
        • Output status (ON or OFF)
        • Additional information in certain circumstances (detailed in Section III of User Manual)
        • Lifetime Warranty on product
        • Lifetime Connected Equipment Warranty

           

          Specifications

          15/20 Amp Models

          XG-PCS-15D (120 Volt, 15 Amp)
          XG-PCS-20D (120 Volt, 20 Amp)
          XG-PCS-20815D (208-240 Volt, 15 Amp)
          XG-PCS-20820D (208-240 Volt, 20 Amp)
          XG-PCS-IC-1 (Interface Cord, 1 Cord – Sold Separately)

          Physical

          Dimensions: 6.125” W x 8.375” D x 2” H
          Weight: 2.4 lb. (XG-PCS-15D / XG-PCS-20D), 2.6 lb. (XG-PCS-20815D / XG-PCS-20820D)
          Temperature Range: 5C to 35C
          Humidity Range: 5% to 95% R.H. Non-condensing

          Electrical

          Load Rating: 15/20 Amps at 120 Volts (XG-PCS-15D / XG-PCS-20D), 15/20 Amps at 120/230 Volts Split Phase (XG-PCS-20815D / XG-PCS-20820D)
          Voltage Protection Rating (VPR): 330V All Modes (XG-PCS-15D / XG-PCS-20D), 500V L-G, 800V L-L (XG-PCS-20815D / XG-PCS-20820D)
          Attenuation:
          – Normal Mode: >30dB 80kHz – 50MHz
          – Common Mode: >30dB 70kHz – 50MHz (XG-PCS-15D / XG-PCS-20D),
          >30dB 200kHz – 50MHz (XG-PCS-20815D / XG-PCS-20820D)
          Power Requirement (no load): 4 Watts
          Under-Voltage Shutdown: Adjustable from 80 Volts to 95 Volts, or Disabled.
          – Restores at 105 Volts. (XG-PCS-15D / XG-PCS-20D) Adjustable from 140 Volts to 170 Volts, or Disabled.
          – Restores at 190 Volts. (XG-PCS-20815D / XG-PCS-20820D)
          Over-Voltage Shutdown: Adjustable from 135 Volts to 160 Volts.
          – Restores at 130 Volts. (XG-PCS-15D / XG-PCS-20D) Adjustable from 260 Volts to 300 Volts.
          – Restores at 250 Volts. (XG-PCS-20815D / XG-PCS-20820D)
          Internal Memory Capacity: 60 Events with timestamp; 999 counts of each event type
          Voltmeter Accuracy: Peak reading type. Typical product accuracy is ±2% between:
          40V and 180V: (XG-PCS-15D / XG-PCS-20D)
          100V and 300V: (XG-PCS-20815D / XG-PCS-20820D)
          Timestamp accuracy: ±2.5%
          Response Time: 100msec Over-Voltage / 150msec Under-Voltage
          Under-Voltage Record Event Definition: AC voltage has dropped below:
          100V (XG-PCS-15D / XG-PCS-20D)
          180V (XG-PCS-20815D / XG-PCS-20820D)
          Over-Voltage Record Event Definition: AC voltage has risen above:
          135V (XG-PCS-15D / XG-PCS-20D)
          260V (XG-PCS-20815D / XG-PCS-20820D)
          Power Outage Event Definition: AC voltage has dropped below 20V.
          Surge Event Definition: Next Gen PCS Filter has been exposed to a transient voltage in one of the 3 possible modes (between Live and Neutral, between Live and Ground, between Neutral and Ground) with a peak amplitude of 500V* (XG-PCS-15D / XG-PCS-20D); 700V* (XG-PCS-20815D / XG-PCS-20820D) or higher and a frequency of 20 kHz or higher. *500V/700V surge voltage amplitude applies to IEEE C62.41 Category B Impulse; surge voltage amplitudes necessary for detection of other surge types may vary.
          Modem/Fax Protection: Single telephone line surge suppression.
          Ethernet Protection: Cat5e network surge protection, ETL Certified to TIA/EIA-568-B.2.
          Computer Requirements

          PC Requirements: For use with Next Gen PCS Diagnostic Software. Minimum 133MHz Pentium processor (or equivalent), minimum 64MB of RAM, minimum 10MB free hard drive space, VGA or higher resolution monitor, keyboard, mouse, CD or DVD drive, minimum screen resolution of 1024×768, Microsoft Windows 2000/XP/Vista/7.
          Standards Compliance

          Agency Listings: ETL Certified to UL 1449 (3rd Edition), ETL Certified to TIA/EIA-568-B.2 Cat 5e, Industry Canada Certified
          ** Specifications subject to change without notice
          ** All listed specifications obtained at an ambient temperature of 25°C

          30 Amp Models

          XG-PCS-L630 (208-240 Volt, 30 Amp)
          XG-PCS-630 (208-240 Volt, 30 Amp)
          XG-PCS-IC-1 (Interface Cord, 1 Cord – Sold Separately)
          XG-PCS-IC-10 (Interface Cord Bundle, 10 Cords – Sold Separately)


          Physical

          Dimensions: 7.75” W x 4.5” D x 11.25” H
          Weight: 10 lb.
          Temperature Range: 5C to 35C
          Humidity Range: 5% to 95% R.H. Non-condensing

           

          Electrical

          Load Rating: 30 Amps at 120/230 Volts, Split Phase
          Voltage Protection Rating (VPR): 500V L-G, 800V L-L
          Attenuation:
          – Normal Mode: >30dB 80kHz – 50MHz
          – Common Mode: >30dB 200kHz – 50MHz
          Power Requirement (no load): 4 Watts
          Under-Voltage Shutdown:
          – Adjustable from 140 Volts to 170 Volts, or Disabled.
          – Restores at 190 Volts.
          Over-Voltage Shutdown:
          – Adjustable from 260Volts to 300 Volts.
          – Restores at 250 Volts.
          Internal Memory Capacity: 60 Events with timestamp; 999 counts of each event type
          Voltmeter Accuracy: Peak reading type. Typical product accuracy is ±2% between:
          100V and 300V
          Timestamp accuracy: ±2.5%
          Response Time: 100msec Over-Voltage / 150msec Under-Voltage
          Under-Voltage Record Event Definition: AC voltage has dropped below: 180V
          Over-Voltage Record Event Definition: AC voltage has risen above: 260V
          Power Outage Event Definition: AC voltage has dropped below 20V.
          Surge Event Definition: Next Gen PCS Filter has been exposed to a transient voltage in one of the 3 possible modes (between Live and Neutral, between Live and Ground, between Neutral and Ground) with a peak amplitude of 700Volts* or higher and a frequency of 20 kHz or higher.
          *700V surge voltage amplitude applies to IEEE C62.41 Category B Impulse; surge voltage amplitudes necessary for detection of other surge types may vary.
          Modem/Fax Protection: Single telephone line surge suppression.
          Ethernet Protection: Cat5e network surge protection, ETL Certified to TIA/EIA-568-B.2.
          Computer Requirements PC Requirements: For use with Next Gen PCS Diagnostic Software. Minimum 133MHz Pentium processor (or equivalent), minimum 64MB of RAM, minimum 10MB free hard drive space, VGA or higher resolution monitor, keyboard, mouse, CD or DVD drive, minimum screen resolution of 1024×768, Microsoft Windows 2000/XP/Vista/7.
          Standards Compliance Agency Listings: ETL Certification to UL 1449 (3rd Edition) – in process, ETL Certified to TIA/EIA-568-B.2 Cat 5e, Industry Canada Certified
          ** Specifications subject to change without notice
          ** All listed specifications obtained at an ambient temperature of 25°C

          Accessories

          ESP Interface Cable #XG-PCS-IC-1 for connecting Next Gen to PC via USB port. This allows Next Gen power data to be downloaded to PC and/or viewed in real time on the PC. Requires that (free) Next Gen software be installed on host PC.

          Warranty

          Documentation

          Software